Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (84)

Search Parameters:
Keywords = on-orbit radiometric calibration

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 2561 KB  
Article
JPSS-4 VIIRS Pre-Launch Calibration Performance and Assessment
by Amit Angal, David Moyer, Xiaoxiong Xiong, Daniel Link, Thomas Schwarting, Jeff McIntire, Qiang Ji and Chengbo Sun
Remote Sens. 2025, 17(13), 2146; https://doi.org/10.3390/rs17132146 - 23 Jun 2025
Viewed by 427
Abstract
The Joint Polar Satellite System (JPSS) is a collaborative program between NASA and NOAA to provide scientific measurements from multiple polar-orbiting satellites. The development, testing, launch, and operation of the satellites is jointly overseen by NASA and NOAA, with NASA responsible for developing [...] Read more.
The Joint Polar Satellite System (JPSS) is a collaborative program between NASA and NOAA to provide scientific measurements from multiple polar-orbiting satellites. The development, testing, launch, and operation of the satellites is jointly overseen by NASA and NOAA, with NASA responsible for developing and building instruments, spacecraft, ground systems, and launching into orbit. While three VIIRS instruments are currently on-orbit, spacecraft integration of the two VIIRS instruments planned for launch on the JPSS-3 and -4 spacecraft is ongoing. The latest build in the series, set to be launched on the JPSS-4 platform, recently completed its main ground calibration program at the vendor facility. This program covered a comprehensive series of performance metrics designed to ensure that the instrument can maintain its calibration successfully on-orbit. In this paper, we present the results from the radiometric calibration process, which includes metrics such as dynamic range, signal-to-noise ratio, noise equivalent differential temperature, polarization sensitivity, scattered light response, relative spectral response, response versus scan angle, and crosstalk. All key metrics have met or exceeded their design requirements, with some minor exceptions. Also included are comparisons with previous VIIRS instruments, as well as a description of their expected performance once on-orbit. Full article
(This article belongs to the Collection The VIIRS Collection: Calibration, Validation, and Application)
Show Figures

Figure 1

27 pages, 13502 KB  
Article
Use of Radiative Transfer Model for Inter-Satellite Microwave Radiometer Calibration
by Patrick N. De La Llana, Faisal Bin Kashem and W. Linwood Jones
Remote Sens. 2025, 17(9), 1519; https://doi.org/10.3390/rs17091519 - 25 Apr 2025
Viewed by 642
Abstract
This paper describes the benefits of using a microwave radiative transfer model (RTM) to improve the inter-satellite radiometric calibration (XCAL) between two independent satellite microwave radiometers. Because this work was sponsored by the NASA Global Precipitation Mission, the emphasis of this paper is [...] Read more.
This paper describes the benefits of using a microwave radiative transfer model (RTM) to improve the inter-satellite radiometric calibration (XCAL) between two independent satellite microwave radiometers. Because this work was sponsored by the NASA Global Precipitation Mission, the emphasis of this paper is on radiometer channels that are used for atmospheric precipitation retrievals; however, this technique is applicable for microwave remote sensing in general, over a wide range of satellite remote-sensing applications. An XCAL example is presented for the NASA Global Precipitation Mission, whereby the GPM Microwave Imager is used to calibrate another microwave radiometer (TROPICS) within the GPM constellation of satellites. This approach involves intercomparing near-simultaneous measured brightness temperatures from these radiometers viewing a common homogeneous ocean scene. The double difference between observed and theoretical brightness temperature, derived using a radiative transfer model, is used to establish a radiometric calibration offset or bias. On-orbit comparisons are presented for two different approaches, namely, with and without the aid of the RTM. The results demonstrate significant improvements in the XCAL biases derived when using the RTM, and this is especially beneficial when one radiometer produces anomalous brightness temperatures. Full article
(This article belongs to the Special Issue Surface Radiative Transfer: Modeling, Inversion, and Applications)
Show Figures

Figure 1

70 pages, 53631 KB  
Article
Absolute Vicarious Calibration, Extended PICS (EPICS) Based De-Trending and Validation of Hyperspectral Hyperion, DESIS, and EMIT
by Harshitha Monali Adrija, Larry Leigh, Morakot Kaewmanee, Dinithi Siriwardana Pathiranage, Juliana Fajardo Rueda, David Aaron and Cibele Teixeira Pinto
Remote Sens. 2025, 17(7), 1301; https://doi.org/10.3390/rs17071301 - 5 Apr 2025
Cited by 1 | Viewed by 862
Abstract
This study addresses the critical need for radiometrically accurate and consistent hyperspectral data as the remote sensing community moves towards a hyperspectral world. Previous calibration efforts on Hyperion, the first on-orbit hyperspectral sensors, have exhibited temporal stability and absolute accuracy limitations. This work [...] Read more.
This study addresses the critical need for radiometrically accurate and consistent hyperspectral data as the remote sensing community moves towards a hyperspectral world. Previous calibration efforts on Hyperion, the first on-orbit hyperspectral sensors, have exhibited temporal stability and absolute accuracy limitations. This work has developed and validated a novel cross-calibration methodology to address these challenges. Also, this work adds two other hyperspectral sensors, DLR Earth Sensing Imaging Spectrometer (DESIS) and Earth Surface mineral Dust Source Investigation instrument (EMIT), to maintain temporal continuity and enhance spatial coverage along with spectral resolution. The study established a robust approach for calibrating Hyperion using DESIS and EMIT. The methodology involves several key processes. First is a temporal stability assessment on Extended Pseudo Invariant Calibration Sites (EPICS) Cluster13–Global Temporal Stable (GTS) over North Africa (Cluster13–GTS) using Landsat Sensors Landsat 7 (ETM+), Landsat 8 (OLI). Second, a temporal trend correction model was developed for DESIS and Hyperion using statistically selected models. Third, absolute calibration was developed for DESIS and EMIT using multiple vicarious calibration sites, resulting in an overall absolute calibration uncertainty of 2.7–5.4% across the DESIS spectrum and 3.1–6% on non-absorption bands for EMIT. Finally, Hyperion was cross-calibrated using calibrated DESIS and EMIT as reference (with traceability to ground reference) with a calibration uncertainty within the range of 7.9–12.9% across non-absorption bands. The study also validates these calibration coefficients using OLI over Cluster13–GTS. The validation provided results suggesting a statistical similarity between the absolute calibrated hyperspectral sensors mean TOA (top-of-atmosphere) reflectance with that of OLI. This study offers a valuable contribution to the community by fulfilling the above-mentioned needs, enabling more reliable intercomparison, and combining multiple hyperspectral datasets for various applications. Full article
Show Figures

Figure 1

20 pages, 7144 KB  
Article
A Study of NOAA-20 VIIRS Band M1 (0.41 µm) Striping over Clear-Sky Ocean
by Wenhui Wang, Changyong Cao, Slawomir Blonski and Xi Shao
Remote Sens. 2025, 17(1), 74; https://doi.org/10.3390/rs17010074 - 28 Dec 2024
Cited by 3 | Viewed by 979
Abstract
The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the National Oceanic and Atmospheric Administration-20 (NOAA-20) satellite was launched on 18 November 2017. The on-orbit calibration of the NOAA-20 VIIRS visible and near-infrared (VisNIR) bands has been very stable over time. However, NOAA-20 operational [...] Read more.
The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the National Oceanic and Atmospheric Administration-20 (NOAA-20) satellite was launched on 18 November 2017. The on-orbit calibration of the NOAA-20 VIIRS visible and near-infrared (VisNIR) bands has been very stable over time. However, NOAA-20 operational M1 (a dual gain band with a center wavelength of 0.41 µm) sensor data records (SDR) have exhibited persistent scene-dependent striping over clear-sky ocean (high gain, low radiance) since the beginning of the mission, different from other VisNIR bands. This paper studies the root causes of the striping in the operational NOAA-20 M1 SDRs. Two potential factors were analyzed: (1) polarization effect-induced striping over clear-sky ocean and (2) imperfect on-orbit radiometric calibration-induced striping. NOAA-20 M1 is more sensitive to the polarized lights compared to other NOAA-20 short-wavelength bands and the similar bands on the Suomi NPP and NOAA-21 VIIRS, with detector and scan angle-dependent polarization sensitivity up to ~6.4%. The VIIRS M1 top of atmosphere radiance is dominated by Rayleigh scattering over clear-sky ocean and can be up to ~70% polarized. In this study, the impact of the polarization effect on M1 striping was investigated using radiative transfer simulation and a polarization correction method similar to that developed by the NOAA ocean color team. Our results indicate that the prelaunch-measured polarization sensitivity and the polarization correction method work well and can effectively reduce striping over clear-sky ocean scenes by up to ~2% at near nadir zones. Moreover, no significant change in NOAA-20 M1 polarization sensitivity was observed based on the data analyzed in this study. After the correction of the polarization effect, residual M1 striping over clear-sky ocean suggests that there exists half-angle mirror (HAM)-side and detector-dependent striping, which may be caused by on-orbit radiometric calibration errors. HAM-side and detector-dependent striping correction factors were analyzed using deep convective cloud (DCC) observations (low gain, high radiances) and verified over the homogeneous Libya-4 desert site (low gain, mid-level radiance); neither are significantly affected by the polarization effect. The imperfect on-orbit radiometric calibration-induced striping in the NOAA operational M1 SDR has been relatively stable over time. After the correction of the polarization effect, the DCC-based striping correction factors can further reduce striping over clear-sky ocean scenes by ~0.5%. The polarization correction method used in this study is only effective over clear-sky ocean scenes that are dominated by the Rayleigh scattering radiance. The DCC-based striping correction factors work well at all radiance levels; therefore, they can be deployed operationally to improve the quality of NOAA-20 M1 SDRs. Full article
(This article belongs to the Collection The VIIRS Collection: Calibration, Validation, and Application)
Show Figures

Figure 1

20 pages, 7294 KB  
Article
Prelaunch Reflective Solar Band Radiometric Performance of JPSS-3 and -4 VIIRS
by Amit Angal, David Moyer, Xiaoxiong Xiong, Qiang Ji and Daniel Link
Remote Sens. 2024, 16(24), 4799; https://doi.org/10.3390/rs16244799 - 23 Dec 2024
Cited by 1 | Viewed by 758
Abstract
The Joint Polar Satellite System 3 (JPSS-3) and -4 (JPSS-4) Visible Infrared Imaging Radiometer Suite (VIIRS) instruments are the last in the series (S-NPP VIIRS launched in October 2011, JPSS-1 VIIRS launched in November 2017, and JPSS-2 VIIRS launched in November 2022) of [...] Read more.
The Joint Polar Satellite System 3 (JPSS-3) and -4 (JPSS-4) Visible Infrared Imaging Radiometer Suite (VIIRS) instruments are the last in the series (S-NPP VIIRS launched in October 2011, JPSS-1 VIIRS launched in November 2017, and JPSS-2 VIIRS launched in November 2022) of highly advanced polar-orbiting environmental satellites. Both instruments underwent a comprehensive sensor-level thermal vacuum (TVAC) testing at the Raytheon Technologies El Segundo facility to characterize the spatial, spectral, and radiometric aspects of the VIIRS sensor performance. This paper focuses on the radiometric performance of the 14 reflective solar bands (RSBs) that cover the wavelength range from 0.41 to 2.3 µm. Key instrument calibration parameters such as instrument gain, signal-to-noise ratio (SNR), dynamic range, and radiometric calibration uncertainty were derived from the TVAC measurements for both the primary and redundant electronics at three instrument temperature plateaus: cold, nominal, and hot. This paper shows that all the JPSS-3 and -4 VIIRS RSB detectors have been well characterized, with key performance metrics comparable to the previous VIIRS instruments on-orbit. The radiometric calibration uncertainty of the RSBs is within the 2% requirement, except in the case of band M1 of JPSS-4. Comparison of the radiometric performance to sensor requirements, as well as a summary of key instrument testing and performance issues, is also presented. Full article
(This article belongs to the Collection The VIIRS Collection: Calibration, Validation, and Application)
Show Figures

Figure 1

31 pages, 8626 KB  
Article
Calibration and Validation of NOAA-21 Ozone Mapping and Profiler Suite (OMPS) Nadir Mapper Sensor Data Record Data
by Banghua Yan, Trevor Beck, Junye Chen, Steven Buckner, Xin Jin, Ding Liang, Sirish Uprety, Jingfeng Huang, Lawrence E. Flynn, Likun Wang, Quanhua Liu and Warren D. Porter
Remote Sens. 2024, 16(23), 4488; https://doi.org/10.3390/rs16234488 - 29 Nov 2024
Viewed by 1322
Abstract
The Ozone Mapping and Profiler Suites (OMPS) Nadir Mapper (NM) is a grating spectrometer within the OMPS nadir instruments onboard the SNPP, NOAA-20, and NOAA-21 satellites. It is designed to measure Earth radiance and solar irradiance spectra in wavelengths from 300 nm to [...] Read more.
The Ozone Mapping and Profiler Suites (OMPS) Nadir Mapper (NM) is a grating spectrometer within the OMPS nadir instruments onboard the SNPP, NOAA-20, and NOAA-21 satellites. It is designed to measure Earth radiance and solar irradiance spectra in wavelengths from 300 nm to 380 nm for operational retrievals of the nadir total column ozone. This study presents calibration and validation analysis results for the NOAA-21 OMPS NM SDR data to meet the JPSS scientific requirements. The NOAA-21 OMPS SDR calibration derives updates of several previous OMPS algorithms, including the dark current correction algorithm, one-time wavelength registration from ground to on-orbit, daily intra-orbit wavelength shift correction, and stray light correction. Additionally, this study derives an empirical scale factor to remove 2.2% of systematic biases in solar flux data, which were caused by pre-launch solar calibration errors of the OMPS nadir instruments. The validation of the NOAA-21 OMPS SDR data is conducted using various methods. For example, the 32-day average method and radiative transfer model are employed to estimate inter-sensor radiometric calibration differences from either the SNPP or NOAA-20 data. The quality of the NOAA-21 OMPS NM SDR data is largely consistent with that of the SNPP and NOAA-20 OMPS data, with differences generally within ±2%. This meets the scientific requirements, except for some deviations mainly in the dichroic range between 300 nm and 303 nm. The deep convective cloud target approach is used to monitor the stability of NOAA-21 OMPS reflectance above 330 nm, showing a variation of 0.5% over the observed period. Data from the NOAA-21 VIIRS M1 band are used to estimate OMPS NM data geolocation errors, revealing that along-track errors can reach up to 3 km, while cross-track errors are generally within ±1 km. Full article
(This article belongs to the Special Issue Remote Sensing Satellites Calibration and Validation)
Show Figures

Figure 1

18 pages, 5470 KB  
Article
Optical System Design of a Self-Calibrating Real Entrance Pupil Imaging Spectrometer
by Xinrui Wang, Xin Li, Quan Zhang, Yuanjian Shi, Wei Wei and Enchao Liu
Photonics 2024, 11(11), 1072; https://doi.org/10.3390/photonics11111072 - 15 Nov 2024
Cited by 1 | Viewed by 1319
Abstract
Presently, on-orbit calibration methods have several problems, such as low calibration accuracy and broken traceability links, so an urgent need exists to unify traceable and high-precision on-orbit radiometric calibration loads as benchmarks for cross-transfer radiometric calibration. Considering the deficiencies of current on-orbit calibration, [...] Read more.
Presently, on-orbit calibration methods have several problems, such as low calibration accuracy and broken traceability links, so an urgent need exists to unify traceable and high-precision on-orbit radiometric calibration loads as benchmarks for cross-transfer radiometric calibration. Considering the deficiencies of current on-orbit calibration, this paper proposes adjusting the size of the variable diaphragm at the entrance pupil and the integration time to attain large dynamic attenuation, converting the radiometric calibration into absolute geometric calibration of the attenuation device, and realizing a self-calibrating real entrance pupil imaging spectrometer (SCREPIS) that can be directly used to view the Earth and the Sun and quickly obtain apparent reflectance data. An initial structural design method based on the distance between individual mirrors is proposed according to the instrument design requirements. The design of a real entry pupil image-side telecentricity off-axis three-reflector front optical system with a 7° field of view along the slit direction, a 3.7 systematic F-number, and a 93 mm focal length is finally realized, and the system image plane energy is verified to change proportionally to the variable diaphragm area. Finally, the front system and rear Offner optical system are jointly simulated and optically designed. The system provides instrumental support for cross-calibration and theoretical support and a technical basis for planning space-based radiation references. Full article
Show Figures

Figure 1

34 pages, 4554 KB  
Article
Early Mission Calibration Performance of NOAA-21 VIIRS Reflective Solar Bands
by Ning Lei, Xiaoxiong Xiong, Kevin Twedt, Sherry Li, Tiejun Chang, Qiaozhen Mu and Amit Angal
Remote Sens. 2024, 16(19), 3557; https://doi.org/10.3390/rs16193557 - 24 Sep 2024
Cited by 1 | Viewed by 1441
Abstract
The Visible Infrared Imaging Radiometer Suite (VIIRS) is one of the key instruments on the recently launched NOAA-21 (previously known as JPSS-2) satellite. The VIIRS, like its predecessors on the SNPP and NOAA-20 satellites, provides daily global coverage in 22 spectral bands from [...] Read more.
The Visible Infrared Imaging Radiometer Suite (VIIRS) is one of the key instruments on the recently launched NOAA-21 (previously known as JPSS-2) satellite. The VIIRS, like its predecessors on the SNPP and NOAA-20 satellites, provides daily global coverage in 22 spectral bands from 412 nm to 12 μm. The geometrically and radiometrically calibrated observations are the basis for many operational applications and scientific research studies. A total of 14 of the 22 bands are reflective solar bands (RSBs), covering photon wavelengths from 412 nm to 2.25 μm. The RSBs were radiometrically calibrated prelaunch and have been regularly calibrated on orbit through the onboard solar diffuser (SD) and scheduled lunar observations. The on-orbit SD’s reflectance change is determined by the onboard solar diffuser stability monitor (SDSM). We review the calibration algorithms and present the early mission performance of the NASA N21 VIIRS RSBs. Using the calibration data collected at both the yaw maneuver and regular times, we derive the screen transmittance functions. The visible and near-infrared bands’ radiometric gains have been stable, nearly independent of time, and so were the radiometric gains of the shortwave-infrared bands after the second mid-mission outgassing. Further, we assess the Earth-view striping observed in the immediate prior collection (Collection 2.0) and apply a previously developed algorithm to mitigate the striping. The N21 VIIRS RSB detector signal-to-noise ratios are all above the design values with large margins. Finally, the uncertainties of the retrieved Earth-view top-of-the-atmosphere spectral reflectance factors at the respective typical spectral radiance levels are estimated to be less than 1.5% for all the RSBs, except band M11 whose reflectance factor uncertainty is 2.2%. Full article
(This article belongs to the Collection The VIIRS Collection: Calibration, Validation, and Application)
Show Figures

Figure 1

20 pages, 15495 KB  
Article
A General On-Orbit Absolute Radiometric Calibration Method Compatible with Multiple Imaging Conditions
by Liming Fan, Zhongjin Jiang, Shuhai Yu, Yunhe Liu, Dong Wang and Maosheng Chen
Remote Sens. 2024, 16(18), 3503; https://doi.org/10.3390/rs16183503 - 21 Sep 2024
Cited by 2 | Viewed by 1978
Abstract
On-orbit absolute radiometric calibration is not only a prerequisite for the quantitative application of optical remote sensing satellite data but also a key step in ensuring the accuracy and reliability of satellite observation data. Due to the diversity of imaging conditions for optical [...] Read more.
On-orbit absolute radiometric calibration is not only a prerequisite for the quantitative application of optical remote sensing satellite data but also a key step in ensuring the accuracy and reliability of satellite observation data. Due to the diversity of imaging conditions for optical remote sensing satellite sensors, on-orbit absolute radiometric calibration usually requires a large number of imaging tasks and manual labor to calibrate each imaging condition. This seriously limits the timeliness of on-orbit absolute radiometric calibration and is also an urgent problem to be solved in the context of the explosive growth of satellite numbers. Based on this, we propose a general on-orbit absolute radiometric calibration method compatible with multiple imaging conditions. Firstly, we use a large amount of laboratory radiometric calibration data to explore the mathematical relationship between imaging conditions (row transfer time, integration level and gain), radiance, and DN, and successfully build an imaging condition compatibility model. Secondly, we combine the imaging condition compatibility model with cross calibration to achieve a general on-orbit absolute radiometric calibration method. We use cross calibration to obtain the reference radiance and corresponding DN of the target satellites, which calculates the general coefficient by using row transfer time, integration level, and gain, and use the general coefficient to calibrate all imaging conditions. Finally, we use multiple imaging tasks of the JL1GF03D11 satellites to verify the effectiveness of the proposed method. The experiments show that the average relative difference was reduced to 2.79% and the RMSE was reduced to 1.51, compared with the laboratory radiometric calibration method. In addition, we also verify the generality of the proposed method by using 10 satellites of the Jilin-1 GF03D series. The experiment shows that the goodness of fit of the general coefficient is all greater than 95%, and the average relative difference between the reference radiance and the calibrated radiance of the proposed method is 2.46%, with an RMSE of 1.67. To sum up, by using the proposed method, all imaging conditions of optical remote sensing satellite sensor can be calibrated in one imaging task, which greatly improves the timeliness and accuracy of on-orbit absolute radiometric calibration. Full article
(This article belongs to the Special Issue Optical Remote Sensing Payloads, from Design to Flight Test)
Show Figures

Graphical abstract

23 pages, 10245 KB  
Article
Preliminary Assessment of On-Orbit Radiometric Calibration Challenges in NOAA-21 VIIRS Reflective Solar Bands (RSBs)
by Taeyoung Choi, Changyong Cao, Slawomir Blonski, Xi Shao, Wenhui Wang and Khalil Ahmad
Remote Sens. 2024, 16(15), 2737; https://doi.org/10.3390/rs16152737 - 26 Jul 2024
Cited by 5 | Viewed by 1446
Abstract
The National Oceanic and Atmospheric Administration (NOAA) 21 Visible Infrared Imaging Radiometer Suite (VIIRS) was successfully launched on 10 November 2022. To ensure the required instrument performance, a series of Post-Launch Tests (PLTs) were performed and analyzed. The primary calibration source for NOAA-21 [...] Read more.
The National Oceanic and Atmospheric Administration (NOAA) 21 Visible Infrared Imaging Radiometer Suite (VIIRS) was successfully launched on 10 November 2022. To ensure the required instrument performance, a series of Post-Launch Tests (PLTs) were performed and analyzed. The primary calibration source for NOAA-21 VIIRS Reflective Solar Bands (RSBs) is the Solar Diffuser (SD), which retains the prelaunch radiometric calibration standard from prelaunch to on-orbit. Upon reaching orbit, the SD undergoes degradation as a result of ultraviolet solar illumination. The rate of SD degradation (called the H-factor) is monitored by a Solar Diffuser Stability Monitor (SDSM). The initial H-factor’s instability was significantly improved by deriving a new sun transmittance function from the yaw maneuver and one-year SDSM data. The F-factors (normally represent the inverse of instrument gain) thus calculated for the Visible/Near-Infrared (VISNIR) bands were proven to be stable throughout the first year of the on-orbit operations. On the other hand, the Shortwave Infrared (SWIR) bands unexpectedly showed fast degradation, which is possibly due to unknown substance accumulation along the optical path. To mitigate these SWIR band gain changes, the NOAA VIIRS Sensor Data Record (SDR) team used an automated calibration software package called RSBautoCal. In March 2024, the second middle-mission outgassing event to reverse SWIR band degradation was shown to be successful and its effects are closely monitored. Finally, the deep convective cloud trends and lunar collection results validated the operational F-factors. This paper summarizes the preliminary on-orbit radiometric calibration updates and performance for the NOAA-21 VIIRS SDR products in the RSB. Full article
(This article belongs to the Collection The VIIRS Collection: Calibration, Validation, and Application)
Show Figures

Figure 1

20 pages, 8679 KB  
Article
Estimation of Infrared Stellar Flux Based on Star Catalogs with I-GWO for Stellar Calibration
by Yang Hong, Peng Rao, Yuxing Zhou and Xin Chen
Remote Sens. 2024, 16(12), 2198; https://doi.org/10.3390/rs16122198 - 17 Jun 2024
Viewed by 1422
Abstract
As on-orbit space cameras evolve toward larger apertures, wider fields of view, and deeper cryogenic environments, achieving absolute radiometric calibration using an all-optical path blackbody reference source in orbit becomes increasingly challenging. Consequently, stars have emerged as a novel in-orbit standard source. However, [...] Read more.
As on-orbit space cameras evolve toward larger apertures, wider fields of view, and deeper cryogenic environments, achieving absolute radiometric calibration using an all-optical path blackbody reference source in orbit becomes increasingly challenging. Consequently, stars have emerged as a novel in-orbit standard source. However, due to differences in camera bands, directly obtaining the stellar radiance flux corresponding to specific camera bands is not feasible. In order to address this challenge, we propose a method for estimating radiance flux based on the MSX star catalog, which integrates a dual-band thermometry method with an improved grey wolf optimization (I-GWO) algorithm. In an experiment, we analyzed 351 stars with temperatures ranging from 4000 to 7000 K. The results indicate that our method achieved a temperature estimation accuracy of less than 10% for 83.5% of the stars, with an average estimation error of 5.82%. Compared with previous methods based on star catalogs, our approach significantly enhanced the estimation accuracy by 75.4%, improved algorithm stability by 91.3%, and reduced the computation time to only 3% of that required by other methods. Moreover, the on-orbit star calibration error using our stellar radiance flux estimation method remained within 5%. This study effectively leveraged the extensive data available in star catalogs, providing substantial support for the development of an infrared star calibration network, which holds significant value for the in-orbit calibration of large-aperture cameras. Future research will explore the potential applicability of this method across different spectral bands. Full article
(This article belongs to the Special Issue Remote Sensing Satellites Calibration and Validation)
Show Figures

Figure 1

24 pages, 8043 KB  
Article
Pre-Launch Polarization Assessment of JPSS-3 and -4 VIIRS VNIR Bands and Comparison with Previous Builds
by David Moyer, Jeff McIntire, Amit Angal and Xiaoxiong Xiong
Remote Sens. 2024, 16(12), 2178; https://doi.org/10.3390/rs16122178 - 15 Jun 2024
Cited by 3 | Viewed by 1301
Abstract
The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument, deployed on multiple satellites including the Suomi National Polar-orbiting Partnership (S-NPP), National Oceanic and Atmospheric Administration 20 (NOAA-20), NOAA-21, Joint Polar Satellite System (JPSS-3), and JPSS-4 spacecraft, with launches in 2011, 2017, 2022, 2032, and [...] Read more.
The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument, deployed on multiple satellites including the Suomi National Polar-orbiting Partnership (S-NPP), National Oceanic and Atmospheric Administration 20 (NOAA-20), NOAA-21, Joint Polar Satellite System (JPSS-3), and JPSS-4 spacecraft, with launches in 2011, 2017, 2022, 2032, and 2027, respectively, has polarization sensitivity that affects the at-aperture radiometric Sensor Data Record (SDR) calibration in the Visible Near InfraRed (VNIR) spectral region. These SDRs are key inputs into the VIIRS atmospheric, land, and water Environmental Data Records (EDRs) that are integral to weather and climate applications. If the polarization sensitivity of the VIIRS instrument is left uncorrected, EDR quality will degrade, causing diminished quality of weather and climate data. Pre-launch characterization of the instrument’s polarization sensitivity was performed to mitigate this on-orbit calibration effect and improve the quality of the EDRs. Specialized ground test equipment, built specifically for the VIIRS instrument, enabled high-fidelity characterization of the instrument’s polarization performance. This paper will discuss the polarization sensitivity characterization test approach, methodology, and results for the JPSS-3 and -4 builds. This includes a description of the ground test equipment, instrument requirements, and how the testing was executed and analyzed. A comparison of the polarization sensitivity results of the on-orbit S-NPP, NOAA-20, and -21 instruments with the JPSS-3 and -4 VIIRS instruments will be discussed as well. Full article
(This article belongs to the Section Satellite Missions for Earth and Planetary Exploration)
Show Figures

Figure 1

27 pages, 2083 KB  
Article
A Wide-Angle Hyperspectral Top-of-Atmosphere Reflectance Model for the Libyan Desert
by Fuxiang Guo, Xiaobing Zheng, Yanna Zhang, Wei Wei, Zejie Zhang, Quan Zhang and Xin Li
Remote Sens. 2024, 16(8), 1406; https://doi.org/10.3390/rs16081406 - 16 Apr 2024
Cited by 3 | Viewed by 1471
Abstract
Reference targets with stability, uniformity, and known reflectance on the Earth’s surface, such as deserts, can be used for the absolute radiometric calibration of satellite sensors. A wide-angle hyperspectral reflectance model at the top of atmosphere (TOA) over such a reference target will [...] Read more.
Reference targets with stability, uniformity, and known reflectance on the Earth’s surface, such as deserts, can be used for the absolute radiometric calibration of satellite sensors. A wide-angle hyperspectral reflectance model at the top of atmosphere (TOA) over such a reference target will expand the applicability of on-orbit calibration to different spectral bands and angles. To achieve the long-term, continuous, and high-precision absolute radiometric calibration of remote sensors, a wide-angle hyperspectral TOA reflectance model of the Libyan Desert was constructed based on spectral reflectance data, satellite overpass parameters, and atmospheric parameters from the Terra/Aqua and Earth Observation-1 (EO-1) satellites between 2003 and 2012. By means of angle fitting, viewing angle grouping, and spectral extension, the model is applicable for absolute radiometric calibration of the visible to short-wave infrared (SWIR) bands for sensors within viewing zenith angles of 65 degrees. To validate the accuracy and precision of the model, a total of 3120 long-term validations of model accuracy and 949 cross-validations with the Landsat 8 Operational Land Imager (OLI) and Suomi National Polar-Orbiting Partnership (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) satellite sensors between 2013 and 2020 were conducted. The results show that the TOA reflectance calculated by the model had a standard deviation (SD) of relative differences below 1.9% and a root-mean-square error (RMSE) below 0.8% when compared with observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) and Landsat 8 OLI. The SD of the relative differences and the RMSE were within 2.7% when predicting VIIRS data. Full article
(This article belongs to the Special Issue Remote Sensing Satellites Calibration and Validation)
Show Figures

Graphical abstract

28 pages, 4685 KB  
Article
Landsat 9 Transfer to Orbit of Pre-Launch Absolute Calibration of Operational Land Imager (OLI)
by Raviv Levy, Jeffrey A. Miller, Julia A. Barsi, Kurtis J. Thome and Brian L. Markham
Remote Sens. 2024, 16(8), 1360; https://doi.org/10.3390/rs16081360 - 12 Apr 2024
Cited by 2 | Viewed by 1759
Abstract
Landsat 9 Operational Land Imager (L9-OLI) was launched on 27 September 2021, after completing a successful radiometric pre-launch calibration and characterization phase. The radiometric math model that governs the ground system—the data processing and analysis system (DPAS)—uses various calibration parameters that had been [...] Read more.
Landsat 9 Operational Land Imager (L9-OLI) was launched on 27 September 2021, after completing a successful radiometric pre-launch calibration and characterization phase. The radiometric math model that governs the ground system—the data processing and analysis system (DPAS)—uses various calibration parameters that had been derived based on the pre-launch tests and analysis. During the on-orbit commissioning phase, the OLI system acquired specific sets of data collects, which enabled the revalidation of the pre-launch absolute calibration scale and other associated instrument performance characteristics. The analysis results shown in this paper focus on the activities and results related to the transfer-to-orbit analysis for the SI-traceable pre-launch radiometric scale. Key topics discussed in this paper include: radiance and reflectance calibration parameters for OLI; solar diffuser collects; stimulation-lamp collects; dark response; signal-to-noise ratios; and noise characteristics; radiometric response stability and the on-orbit update to the radiance to reflectance conversion factors. It will be shown that the OLI response during the early on-orbit operation matched pre-launch results and therefore this re-validates the absolute radiometric scaling at the predicted pre-launch level within the expected level of uncertainties. The launch did not cause any significant changes to the OLI system from the perspective of the absolute radiometric calibration performance. Once the transfer to orbit of the absolute calibration was confirmed, it created a solid basis for further on-orbit refinements of the radiance calibration parameters. As such, follow-on calibration refinements are discussed in other articles within this special issue, and they address issues such as uniformity as well as cross-calibration activities. Full article
Show Figures

Figure 1

22 pages, 15570 KB  
Article
Time-Series Cross-Radiometric Calibration and Validation of GF-6/WFV Using Multi-Site
by Yingxian Wang, Yaokai Liu, Weiwei Zhao, Jian Zeng, Huixian Wang, Renfei Wang, Zhaopeng Xu and Qijin Han
Remote Sens. 2024, 16(7), 1287; https://doi.org/10.3390/rs16071287 - 5 Apr 2024
Cited by 5 | Viewed by 2208
Abstract
The GaoFen6 (GF-6) satellite, equipped with a wide full-swath (WFV) sensor, offers high spatial resolution and extensive coverage, making it widely utilized in agricultural and forestry classification, land resource monitoring, and other fields. Accurate on-orbit radiometric calibration of GF-6/WFV is crucial for these [...] Read more.
The GaoFen6 (GF-6) satellite, equipped with a wide full-swath (WFV) sensor, offers high spatial resolution and extensive coverage, making it widely utilized in agricultural and forestry classification, land resource monitoring, and other fields. Accurate on-orbit radiometric calibration of GF-6/WFV is crucial for these quantitative applications. Currently, the absolute radiometric calibration of GF-6/WFV relies primarily on vicarious calibration conducted by the China Center for Resources Satellite Data and Application (CRESDA). However, annual vicarious calibration may not adequately capture the radiometric performance of GF-6/WFV due to performance degradation. Therefore, increasing the frequency of on-orbit radiometric calibration throughout the lifetime of GF-6/WFV is essential. This study proposes a method for conducting long-term cross-radiometric calibrations of GF-6/WFV by taking the multispectral imager (MSI) onboard the Sentinel-2 satellite as a reliable reference sensor and the sites from RadCalNet as reference ground targets. Firstly, we conducted 62 on-orbit cross-radiometric calibrations of GF-6/WFV since its launch by tracking with the Sentinel-2/MSI sensor after correcting the discrepancy spectrum and solar zenith angle. Then, validation of cross-radiometric calibration results against RadCalNet products indicated an average absolute relative error between 3.55% and 4.64%. Cross-validation with additional reference sensors, including Landsat-8/OLI and MODIS, confirmed the reliability of calibration, demonstrating relative differences from GF-6/WFV of less than 5%. Furthermore, the overall uncertainty of the cross-radiometric calibration was estimated to be from 4.08% to 4.89%. Finally, trend analysis of the time-series radiometric performance was also conducted and revealed an annual degradation rate ranging from 0.57% to 2.31%. This degradation affects surface reflectance retrieval, introducing a bias of approximately 0.0073 to 0.0084. Our findings highlight the operational effectiveness of the proposed method in achieving long-time-series on-orbit radiometric calibration and degradation monitoring of GF-6/WFV. The study also demonstrates that the radiometric performance of GF-6/WFV is relatively stable and suitable for further quantitative applications, especially for long-term monitoring applications. Full article
(This article belongs to the Special Issue Remote Sensing Satellites Calibration and Validation)
Show Figures

Figure 1

Back to TopTop