Search Results (18)

Search Parameters:
Keywords = shear horizontal—surface acoustic waves (SH-SAW)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 2694 KB  
Article
Tracking the Risk of Cardiovascular Disease after Almond and Oat Milk Intervene or Statin Medication with a Powerful Reflex SH-SAW POCT Platform
by Chia-Hsuan Cheng, Hiromi Yatsuda, Han-Hsiang Chen, Guang-Huar Young, Szu-Heng Liu and Robert YL Wang
Sensors 2024, 24(20), 6517; https://doi.org/10.3390/s24206517 - 10 Oct 2024
Cited by 3 | Viewed by 4573
Abstract
Cardiovascular disease (CVD) represents the leading cause of death worldwide. For individuals at elevated risk for cardiovascular disease, early detection and monitoring of lipid status is imperative. The majority of lipid measurements conducted in hospital settings employ optical detection, which necessitates the use [...] Read more.
Cardiovascular disease (CVD) represents the leading cause of death worldwide. For individuals at elevated risk for cardiovascular disease, early detection and monitoring of lipid status is imperative. The majority of lipid measurements conducted in hospital settings employ optical detection, which necessitates the use of relatively large-sized detection machines. It is, therefore, necessary to develop point-of-care testing (POCT) for lipoprotein in order to monitor CVD. To enhance the management and surveillance of CVD, this study sought to develop a POCT approach for apolipoprotein B (ApoB) utilizing a shear horizontal surface acoustic wave (SH-SAW) platform to assess the risk of heart disease. The platform employs a reflective SH-SAW sensor to reduce the sensor size and enhance the phase-shifted signals. In this study, the platform was utilized to monitor the impact of a weekly almond and oat milk or statins intervention on alterations in CVD risk. The SH-SAW ApoB test exhibited a linear range of 0 to 212 mg/dL, and a coefficient correlation (R) of 0.9912. Following a four-week intervention period, both the almond and oat milk intervention (−23.3%, p < 0.05) and statin treatment (−53.1%, p < 0.01) were observed to significantly reduce ApoB levels. These findings suggest that the SH-SAW POCT device may prove a valuable tool for monitoring CVD risk, particularly during routine daily or weekly follow-up visits. Full article
(This article belongs to the Special Issue Portable Biosensors for Rapid Detection)
Show Figures

Figure 1

13 pages, 2247 KB  
Article
New Advances in Rapid Pretreatment for Small Dense LDL Cholesterol Measurement Using Shear Horizontal Surface Acoustic Wave (SH-SAW) Technology
by Tai-Hua Chou, Chia-Hsuan Cheng, Chi-Jen Lo, Guang-Huar Young, Szu-Heng Liu and Robert Y-L Wang
Int. J. Mol. Sci. 2024, 25(2), 1044; https://doi.org/10.3390/ijms25021044 - 15 Jan 2024
Cited by 8 | Viewed by 3956
Abstract
Atherosclerosis is an inflammatory disease of the arteries associated with alterations in lipid and other metabolism and is a major cause of cardiovascular disease (CVD). LDL consists of several subclasses with different sizes, densities, and physicochemical compositions. Small dense LDL (sd-LDL) is a [...] Read more.
Atherosclerosis is an inflammatory disease of the arteries associated with alterations in lipid and other metabolism and is a major cause of cardiovascular disease (CVD). LDL consists of several subclasses with different sizes, densities, and physicochemical compositions. Small dense LDL (sd-LDL) is a subclass of LDL. There is growing evidence that sd-LDL-C is associated with CVD risk, metabolic dysregulation, and several pathophysiological processes. In this study, we present a straightforward membrane device filtration method that can be performed with simple laboratory methods to directly determine sd-LDL in serum without the need for specialized equipment. The method consists of three steps: first, the precipitation of lipoproteins with magnesium harpin; second, the collection of effluent from a 100 nm filter; and third, the quantification of sd-LDL-ApoB in the effluent with an SH-SAW biosensor. There was a good correlation between ApoB values obtained using the centrifugation (y = 1.0411x + 12.96, r = 0.82, n = 20) and filtration (y = 1.0633x + 15.13, r = 0.88, n = 20) methods and commercially available sd-LDL-C assay values. In addition to the filtrate method, there was also a close correlation between sd-LDL-C and ELISA assay values (y = 1.0483x − 4489, r = 0.88, n = 20). The filtration treatment method also showed a high correlation with LDL subfractions and NMR spectra ApoB measurements (y = 2.4846x + 4.637, r = 0.89, n = 20). The presence of sd-LDL-ApoB in the effluent was also confirmed by ELISA assay. These results suggest that this filtration method is a simple and promising pretreatment for use with the SH-SAW biosensor as a rapid in vitro diagnostic (IVD) method for predicting sd-LDL concentrations. Overall, we propose a very sensitive and specific SH-SAW biosensor with the ApoB antibody in its sensitive region to monitor sd-LDL levels by employing a simple delay-time phase shifted SH-SAW device. In conclusion, based on the demonstration of our study, the SH-SAW biosensor could be a strong candidate for the future measurement of sd-LDL. Full article
(This article belongs to the Special Issue Biosensors for the Early Diagnosis of High-Impact Human Diseases)
Show Figures

Figure 1

13 pages, 1652 KB  
Review
Application of Shear Horizontal Surface Acoustic Wave (SH-SAW) Immunosensor in Point-of-Care Diagnosis
by Chia-Hsuan Cheng, Hiromi Yatsuda, Mikihiro Goto, Jun Kondoh, Szu-Heng Liu and Robert Y. L. Wang
Biosensors 2023, 13(6), 605; https://doi.org/10.3390/bios13060605 - 1 Jun 2023
Cited by 16 | Viewed by 5569
Abstract
Point-of-care testing (POCT), also known as on-site or near-patient testing, has been exploding in the last 20 years. A favorable POCT device requires minimal sample handling (e.g., finger-prick samples, but plasma for analysis), minimal sample volume (e.g., one drop of blood), and very [...] Read more.
Point-of-care testing (POCT), also known as on-site or near-patient testing, has been exploding in the last 20 years. A favorable POCT device requires minimal sample handling (e.g., finger-prick samples, but plasma for analysis), minimal sample volume (e.g., one drop of blood), and very fast results. Shear horizontal surface acoustic wave (SH-SAW) biosensors have attracted a lot of attention as one of the effective solutions to complete whole blood measurements in less than 3 min, while providing a low-cost and small-sized device. This review provides an overview of the SH-SAW biosensor system that has been successfully commercialized for medical use. Three unique features of the system are a disposable test cartridge with an SH-SAW sensor chip, a mass-produced bio-coating, and a palm-sized reader. This paper first discusses the characteristics and performance of the SH-SAW sensor system. Subsequently, the method of cross-linking biomaterials and the analysis of SH-SAW real-time signals are investigated, and the detection range and detection limit are presented. Full article
(This article belongs to the Special Issue Acoustic Wave Biosensors)
Show Figures

Figure 1

10 pages, 3410 KB  
Article
Dual-Passband SAW Filter Based on a 32°YX-LN/SiO2/SiC Multilayered Substrate
by Huiping Xu, Sulei Fu, Rongxuan Su, Peisen Liu, Rui Wang, Fei Zeng, Cheng Song, Weibiao Wang and Feng Pan
Micromachines 2023, 14(2), 479; https://doi.org/10.3390/mi14020479 - 18 Feb 2023
Cited by 7 | Viewed by 4458
Abstract
To meet the demands of highly integrated and miniaturized radio frequency front-end (RFFE) modules, multi-passband filters which support multi-channel compounding come to the foreground. In this work, we proposed a new design of a dual-passband surface acoustic wave (SAW) filter based on a [...] Read more.
To meet the demands of highly integrated and miniaturized radio frequency front-end (RFFE) modules, multi-passband filters which support multi-channel compounding come to the foreground. In this work, we proposed a new design of a dual-passband surface acoustic wave (SAW) filter based on a 32°YX-LiNbO3 (LN)/SiO2/SiC multilayered structure. The filter is of a standalone ladder topology and comprises dual-mode resonators, in which the shear horizontal (SH) mode and high-order SH mode are simultaneously excited through electrode thickness modulation. The impact of electrode thickness on the performance of the dual-mode resonator was systematically investigated by the finite element method (FEM), and resonators were prepared and verified the simulation results. The electromechanical coupling coefficients (K2) of the SH modes are 15.1% and 17.0%, while the maximum Bode-Q (Qmax) values are 150 and 247, respectively, for the fabricated resonators with wavelengths of 1 μm and 1.1 μm. In terms of the high-order SH modes in these resonators, the K2 values are 9.8% and 8.4%, and Qmax values are 190 and 262, respectively. The fabricated dual-band filter shows the center frequencies (fc) of 3065 MHz and 4808 MHz as two bands, with 3-dB fractional bandwidths (FBW) of 5.1% and 5.9%, respectively. Such a dual-band SAW filter based on a conventional ladder topology is meaningful in terms of its compact layout and diminished area occupancy. This work provides a promising avenue to constitute a high-performance dual-passband SAW filter for sub-6 GHz RF application. Full article
(This article belongs to the Special Issue Advanced Electrostatic Sensors and Actuators)
Show Figures

Figure 1

13 pages, 3134 KB  
Article
Carbon SH-SAW-Based Electronic Nose to Discriminate and Classify Sub-ppm NO2
by Carlos Cruz, Daniel Matatagui, Cristina Ramírez, Isidro Badillo-Ramirez, Emmanuel de la O-Cuevas, José M. Saniger and Mari Carmen Horrillo
Sensors 2022, 22(3), 1261; https://doi.org/10.3390/s22031261 - 7 Feb 2022
Cited by 15 | Viewed by 4273
Abstract
In this research, a compact electronic nose (e-nose) based on a shear horizontal surface acoustic wave (SH-SAW) sensor array is proposed for the NO2 detection, classification and discrimination among some of the most relevant surrounding toxic chemicals, such as carbon monoxide (CO), [...] Read more.
In this research, a compact electronic nose (e-nose) based on a shear horizontal surface acoustic wave (SH-SAW) sensor array is proposed for the NO2 detection, classification and discrimination among some of the most relevant surrounding toxic chemicals, such as carbon monoxide (CO), ammonia (NH3), benzene (C6H6) and acetone (C3H6O). Carbon-based nanostructured materials (CBNm), such as mesoporous carbon (MC), reduced graphene oxide (rGO), graphene oxide (GO) and polydopamine/reduced graphene oxide (PDA/rGO) are deposited as a sensitive layer with controlled spray and Langmuir–Blodgett techniques. We show the potential of the mass loading and elastic effects of the CBNm to enhance the detection, the classification and the discrimination of NO2 among different gases by using Machine Learning (ML) techniques (e.g., PCA, LDA and KNN). The small dimensions and low cost make this analytical system a promising candidate for the on-site discrimination of sub-ppm NO2. Full article
Show Figures

Graphical abstract

9 pages, 2591 KB  
Article
Novel SH-SAW Biosensors for Ultra-Fast Recognition of Growth Factors
by Daniel Matatagui, Ágatha Bastida and M. Carmen Horrillo
Biosensors 2022, 12(1), 17; https://doi.org/10.3390/bios12010017 - 30 Dec 2021
Cited by 15 | Viewed by 4551
Abstract
In this study, we investigated a label-free time efficient biosensor to recognize growth factors (GF) in real time, which are of gran interesting in the regulation of cell division and tissue proliferation. The sensor is based on a system of shear horizontal surface [...] Read more.
In this study, we investigated a label-free time efficient biosensor to recognize growth factors (GF) in real time, which are of gran interesting in the regulation of cell division and tissue proliferation. The sensor is based on a system of shear horizontal surface acoustic wave (SH-SAW) immunosensor combined with a microfluidic chip, which detects GF samples in a dynamic mode. In order to prove this method, to our knowledge not previously used for this type of compounds, two different GFs were tested by two immunoreactions: neurotrophin-3 and fibroblast growth factor-2 using its polyclonal antibodies. GF detection was conducted via an enhanced sequential workflow to improve total test time of the immunoassay, which shows that this type of biosensor is a very promising method for ultra-fast recognition of these biomolecules due to its great advantages: portability, simplicity of use, reusability, low cost, and detection within a relatively short period of time. Finally, the biosensor is able to detect FGF-2 growth factor in a concentration wide range, from 1–25 µg/mL, for a total test time of ~15 min with a LOD of 130 ng/mL. Full article
Show Figures

Figure 1

12 pages, 2699 KB  
Article
A Novel Rapid Test to Detect Anti-SARS-CoV-2 N Protein IgG Based on Shear Horizontal Surface Acoustic Wave (SH-SAW)
by Yu-Chi Peng, Chia-Hsuan Cheng, Hiromi Yatsuda, Szu-Heng Liu, Shih-Jen Liu, Takashi Kogai, Chen-Yen Kuo and Robert Y. L. Wang
Diagnostics 2021, 11(10), 1838; https://doi.org/10.3390/diagnostics11101838 - 5 Oct 2021
Cited by 21 | Viewed by 4431
Abstract
Since the Coronavirus disease 2019 (COVID-19) pandemic outbreak, many methods have been used to detect antigens or antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), including viral culture, nucleic acid test, and immunoassay. The shear-horizontal surface acoustic wave (SH-SAW) biosensor is a [...] Read more.
Since the Coronavirus disease 2019 (COVID-19) pandemic outbreak, many methods have been used to detect antigens or antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), including viral culture, nucleic acid test, and immunoassay. The shear-horizontal surface acoustic wave (SH-SAW) biosensor is a novel pathogen detection platform with the advantages of high sensitivity and short detection time. The objective of this study is to develop a SH-SAW biosensor to detect the anti-SARS-CoV-2 nucleocapsid antibody. The rabbit sera collected from rabbits on different days after SARS-CoV-2 N protein injection were evaluated by SH-SAW biosensor and enzyme-linked immunosorbent assay (ELISA). The results showed that the SH-SAW biosensor achieved a high correlation coefficient (R = 0.9997) with different concentrations (34.375–1100 ng/mL) of the “spike-in” anti-N protein antibodies. Compared to ELISA, the SH-SAW biosensor has better sensitivity and can detect anti-N protein IgG signals earlier than ELISA on day 6 (p < 0.05). Overall, in this study, we demonstrated that the SH-SAW biosensor is a promising platform for rapid in vitro diagnostic (IVD) testing, especially for antigen or antibody testing. Full article
Show Figures

Figure 1

17 pages, 4107 KB  
Article
Evaluation of Shear Horizontal Surface Acoustic Wave Biosensors Using “Layer Parameter” Obtained from Sensor Responses during Immunoreaction
by Koji Kano, Hiromi Yatsuda and Jun Kondoh
Sensors 2021, 21(14), 4924; https://doi.org/10.3390/s21144924 - 20 Jul 2021
Cited by 17 | Viewed by 4449
Abstract
Shear horizontal surface acoustic wave (SH-SAW) biosensors measure the reaction of capture antibodies immobilized on the sensing surface to capture test molecules (antigens) by using the change in SH-SAW propagation characteristics. SH-SAW displacement exists not only on the SH-SAW propagating surface, but also [...] Read more.
Shear horizontal surface acoustic wave (SH-SAW) biosensors measure the reaction of capture antibodies immobilized on the sensing surface to capture test molecules (antigens) by using the change in SH-SAW propagation characteristics. SH-SAW displacement exists not only on the SH-SAW propagating surface, but also partially penetrates the specimen liquid to a certain depth, which is determined by the liquid properties of the specimen and the operating frequency of the SH-SAW. This phenomenon is called viscosity penetration. In previous studies, the effect of viscosity penetration was not considered in the measurement of SH-SAW biosensors, and the mass or viscosity change caused by the specific binding of capture antibodies to the target antigen was mainly used for the measurement. However, by considering the effect of viscosity penetration, it was found that the antigen–antibody reaction could be measured and the detection characteristics of the biosensor could be improved. Therefore, this study aims to evaluate the detection properties of SH-SAW biosensors in the surface height direction by investigating the relationship between molecular dimensions and SH-SAW propagation characteristics, which are pseudo-changed by varying the diameter of gold nanoparticles. For the evaluation, we introduced a layer parameter defined by the ratio of the SH-SAW amplitude change to the SH-SAW velocity change caused by the antigen–antibody reaction. We found a correlation between the layer parameter and pseudo-varied molecular dimensions. The results suggest that SH-SAW does not only measure the mass and viscosity but can also measure the size of the molecule to be detected. This shows that SH-SAW biosensors can be used for advanced functionality. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

9 pages, 2417 KB  
Communication
Characterization of Shear Horizontal Waves Using a 1D Laser Doppler Vibrometer
by Alaa Elhady and Eihab M. Abdel-Rahman
Sensors 2021, 21(7), 2467; https://doi.org/10.3390/s21072467 - 2 Apr 2021
Cited by 4 | Viewed by 3227
Abstract
We developed a new technique for the detection of shear horizontal surface acoustic waves (SH-SAW) using a one-dimensional laser-based Doppler vibrometer. It measures the out-of-plane surface deformation at the fingertip of an interdigitated transducer (the boundary of the wave aperture) and uses it [...] Read more.
We developed a new technique for the detection of shear horizontal surface acoustic waves (SH-SAW) using a one-dimensional laser-based Doppler vibrometer. It measures the out-of-plane surface deformation at the fingertip of an interdigitated transducer (the boundary of the wave aperture) and uses it to estimate the instantaneous in-plane displacement field given the substrate Poisson ratio. It can also estimate the degree of surface confinement (wave decay rate). The proposed approach was first verified using finite element analysis (FEA) and demonstrated experimentally using a Bleustein–Gulyaev resonator. Full article
(This article belongs to the Special Issue MEMS and NEMS Sensors)
Show Figures

Figure 1

11 pages, 4264 KB  
Article
Frequency Shift of a SH-SAW Biosensor with Glutaraldehyde and 3-Aminopropyltriethoxysilane Functionalized Films for Detection of Epidermal Growth Factor
by Xue-Chang Lo, Jen-Yu Li, Ming-Tsang Lee and Da-Jeng Yao
Biosensors 2020, 10(8), 92; https://doi.org/10.3390/bios10080092 - 5 Aug 2020
Cited by 27 | Viewed by 6043
Abstract
The frequency shift of a shear-horizontal surface-acoustic-wave (SH-SAW) biosensor in which the concentration of biomolecule is determined by the amount of its adsorption on the sensing film was studied. Simulation results were compared with experimental results to investigate its sensitivity and to develop [...] Read more.
The frequency shift of a shear-horizontal surface-acoustic-wave (SH-SAW) biosensor in which the concentration of biomolecule is determined by the amount of its adsorption on the sensing film was studied. Simulation results were compared with experimental results to investigate its sensitivity and to develop a model to estimate the concentration of a cancer-related biomarker antigen epidermal growth factor (EGF) in the sample, with two types of sensing films, 3-aminopropyltriethoxysilane (APTES) and glutaraldehyde. With the concentration of the targeted biomarker varying from 0.2 to 5 ng/mL, a typical exponential relationship was found between the concentration and the frequency shift of the SH-SAW sensor. Measurement results showed a clear response of this immunosensor to the mass-loading effects of the antibody–antigen. The sensitivity of the glutaraldehyde film is greater than that of the APTES film owing to the chemisorption of the antibody. In the simulation, a shift of the SH-SAW resonant frequency due to added mass occurred on applying an incremental surface mass density on the sensing film, while in real applications, the concentration of the targeted biomarker to be absorbed in the sensing film is demanded. An empirical model was proposed to calculate the frequency shift in the simulation of the SH-SAW biosensor, corresponding to the concentration of specific biomolecules absorbed on a specific film. From the semi-empirical model, the sensitivity level is found to be 0.641 and 1.709 kHz/(ng/mL) for APTES and glutaraldehyde sensing films, respectively, at a biomarker concentration of less than 1 ng/mL. The developed method is useful for quickly estimating the frequency shift with respect to the concentration of the target molecules in the simulation for SH-SAW sensors. Full article
(This article belongs to the Section Biosensor and Bioelectronic Devices)
Show Figures

Figure 1

12 pages, 5024 KB  
Article
Feasibility Study on Shear Horizontal Surface Acoustic Wave Sensors for Engine Oil Evaluation
by Saya Kobayashi and Jun Kondoh
Sensors 2020, 20(8), 2184; https://doi.org/10.3390/s20082184 - 12 Apr 2020
Cited by 13 | Viewed by 3362
Abstract
On site monitoring of engine oil is required. The features of a shear horizontal surface acoustic wave (SH-SAW) sensor include simultaneous detection of mechanical and electrical properties of liquids (such as viscosity, relative permittivity, and conductivity) and loaded mass on the sensor surface. [...] Read more.
On site monitoring of engine oil is required. The features of a shear horizontal surface acoustic wave (SH-SAW) sensor include simultaneous detection of mechanical and electrical properties of liquids (such as viscosity, relative permittivity, and conductivity) and loaded mass on the sensor surface. In this paper, the used engine oil extracted from a motorbike was measured using the SH-SAW sensor. The degradation factors of the used engine oil were experimentally discussed. Especially, the influences of the particles in the engine oil, heating effect, and water contained in the engine oil were considered by comparing the differences between new and used engine oils. The results indicate that the influence of the water contained in the engine oil is the primary cause of the degradation of the used engine oil. Full article
(This article belongs to the Special Issue Acoustic Wave Sensors for Gaseous and Liquid Environments)
Show Figures

Figure 1

12 pages, 4130 KB  
Article
A Three-Dimensional Finite Element Analysis Model for SH-SAW Torque Sensors
by Chao Jiang, Yanqin Chen and Chongdu Cho
Sensors 2019, 19(19), 4290; https://doi.org/10.3390/s19194290 - 3 Oct 2019
Cited by 18 | Viewed by 4976
Abstract
In this paper, a three-dimensional finite element analysis (3D-FEA) model for shear horizontal surface acoustic wave (SH-SAW) torque sensors is presented. Torque sensors play a significant role in various fields to ensure a reliable torque transmission in drivelines. Featured with the advantages of [...] Read more.
In this paper, a three-dimensional finite element analysis (3D-FEA) model for shear horizontal surface acoustic wave (SH-SAW) torque sensors is presented. Torque sensors play a significant role in various fields to ensure a reliable torque transmission in drivelines. Featured with the advantages of high propagation velocity, large Q-value, and good power capacity, SH-SAW based torque sensors are promising but very few studies have been carried out. In order to develop a successful sensor, understanding the characteristics of SH-SAWs produced on piezoelectric substrates and torque sensing modes is indispensable. Therefore, in this study, we first investigated the effect on the generation of waves when different Y-cut quartz substrates are engaged. Thereafter, analyses and comparisons, regarding the effect on the polarized displacement, wave guidance, and wave mode, were conducted for different configurations of wave-guide layer thickness to wavelength ratios (hlayer) and materials. Results show that Y-cut quartz at an angle close to 36° with a gold (Au) layer varying from hAu = 0.02 to 0.03 thickness could be the most effective configuration for the excitation of SH-SAWs, compared to other combinations using platinum (Pt), titanium (Ti) and silicon dioxide (SiO2). Finally, based on the FEA SH-SAW torque sensor model configuring with a Y + 36° quartz substrate and 0.025 λ-thick gold layer, the relationship between the applied torque and sensed voltage was examined, which shows a perfect linearity demonstrating the performance of the sensors. Full article
(This article belongs to the Special Issue Advances in Surface Acoustic Wave Sensors)
Show Figures

Figure 1

14 pages, 879 KB  
Article
On Discovery of the Twelfth and Thirteenth New Nondispersive SH-SAWs in 6 mm Magnetoelectroelastics
by Aleksey Anatolievich Zakharenko
Acoustics 2019, 1(4), 749-762; https://doi.org/10.3390/acoustics1040044 - 20 Sep 2019
Viewed by 3720
Abstract
This report acquaints the reader with an extra two new shear-horizontal surface acoustic waves (SH-SAWs). These new SH-SAWs can propagate along the free surface of the transversely isotropic (6 mm) magnetoelectroelastic materials. These (composite) materials can simultaneously possess the piezoelectric, piezomagnetic, and magnetoelectric [...] Read more.
This report acquaints the reader with an extra two new shear-horizontal surface acoustic waves (SH-SAWs). These new SH-SAWs can propagate along the free surface of the transversely isotropic (6 mm) magnetoelectroelastic materials. These (composite) materials can simultaneously possess the piezoelectric, piezomagnetic, and magnetoelectric effects. Some competition among these effects can lead to suitable solutions found for the following three possible coupling mechanisms: eα – hε, eµ – hα, εµ – α2. Here, the mechanically free interface between the solid and a vacuum was considered. This report discovers the twelfth (thirteenth) new SH-SAW for the magnetically closed (electrically open) case and continuity of both the normal component of the electrical (magnetic) displacement and the electrical (magnetic) potential when the coupling mechanism eα – hε (eµ – hα) works. The propagation velocities were obtained in explicit forms that take into account the contribution of the vacuum material parameters. The discovered waves were then graphically studied for the purpose of disclosing the dissipation phenomenon (the propagation velocity becomes imaginary) caused by the coupling with the vacuum properties. The obtained results can be useful for further investigations of interfacial and plate SH-waves, constitution of technical devices, nondestructive testing and evaluation, and application of some gravitational phenomena. Full article
Show Figures

Figure 1

11 pages, 4441 KB  
Article
Detection of Particulate Matter of Size 2.5 μm with a Surface-Acoustic-Wave Sensor Combined with a Cyclone Separator
by Fung-Yu Kuo, Ying-Chen Lin, Ling-Yi Ke, Chuen-Jinn Tsai and Da-Jeng Yao
Micromachines 2018, 9(8), 398; https://doi.org/10.3390/mi9080398 - 12 Aug 2018
Cited by 18 | Viewed by 5984
Abstract
A device to monitor particulate matter of size 2.5 μm (PM2.5) that has been designed and developed includes a surface-acoustic-wave sensor operating in a shear horizontal mode (SH-SAW) combined with a cyclone separator. In our tests, aerosols generated as incense smoke were first [...] Read more.
A device to monitor particulate matter of size 2.5 μm (PM2.5) that has been designed and developed includes a surface-acoustic-wave sensor operating in a shear horizontal mode (SH-SAW) combined with a cyclone separator. In our tests, aerosols generated as incense smoke were first separated and sampled inside a designed cyclone separator; the sampled PM2.5 was then introduced into the sensing area of an SH-SAW sensor for detection. The use of microcentrifuge tubes as a cyclone separator effectively decreases the size and power consumption of the device; the SAW sensor in a well design and operating at 122 MHz was fabricated with MEMS techniques. After an explanation of the design of the cyclone separator, a simulation of the efficiency and the SAW sensor detection are discussed. A microcentrifuge tube (volume 0.2 mL, inlet and outlet diameters 0.5 mm) as a separator has separation cutoff diameters 50% (d50) at 2.5 μm; the required rate of volumetric flow at the inlet is 0.125 LPM, according to simulation with computational fluid dynamics (CFD) software; the surface-acoustic-wave (SAW) sensor exhibits sensitivity approximately 9 Hz/ng; an experiment for PM2.5 detection conducted with the combined device shows a strong positive linear correlation with a commercial aerosol monitor. The limit of detection (LOD) is 11 μg/m3 with sample time 160 s and total detection duration about 5 min. Full article
(This article belongs to the Special Issue Advanced MEMS/NEMS Technology)
Show Figures

Figure 1

26 pages, 6845 KB  
Review
Surface Acoustic Wave (SAW) for Chemical Sensing Applications of Recognition Layers
by Adnan Mujahid and Franz L. Dickert
Sensors 2017, 17(12), 2716; https://doi.org/10.3390/s17122716 - 24 Nov 2017
Cited by 180 | Viewed by 22079
Abstract
Surface acoustic wave (SAW) resonators represent some of the most prominent acoustic devices for chemical sensing applications. As their frequency ranges from several hundred MHz to GHz, therefore they can record remarkably diminutive frequency shifts resulting from exceptionally small mass loadings. Their miniaturized [...] Read more.
Surface acoustic wave (SAW) resonators represent some of the most prominent acoustic devices for chemical sensing applications. As their frequency ranges from several hundred MHz to GHz, therefore they can record remarkably diminutive frequency shifts resulting from exceptionally small mass loadings. Their miniaturized design, high thermal stability and possibility of wireless integration make these devices highly competitive. Owing to these special characteristics, they are widely accepted as smart transducers that can be combined with a variety of recognition layers based on host-guest interactions, metal oxide coatings, carbon nanotubes, graphene sheets, functional polymers and biological receptors. As a result of this, there is a broad spectrum of SAW sensors, i.e., having sensing applications ranging from small gas molecules to large bio-analytes or even whole cell structures. This review shall cover from the fundamentals to modern design developments in SAW devices with respect to interfacial receptor coatings for exemplary sensor applications. The related problems and their possible solutions shall also be covered, with a focus on emerging trends and future opportunities for making SAW as established sensing technology. Full article
(This article belongs to the Special Issue Surface Acoustic Wave and Bulk Acoustic Wave Sensors)
Show Figures

Figure 1